Functions

  • The T8DCS is a high-performance double-beam spectrophotometer with a variable spectral bandwidth from 0.1-5nm, selected by a continuous variable slit.
  • The instrument is fitted with an embedded PC for extensive local functionality via the UV-Win Software.
  • The Czerny-Turner monochromator with holographic grating keeps stray light to a minimum and offers an excellent optical resolution.
  • The use of a photomultiplier tube as a detector offers exceptional sensitivity.
  • The T8DCS’ true double-beam optical system coupled with an efficient and well-proven electronic control system ensures high stability and low background noise.

Features

  • Photomultiplier tube detection provides exceptional sensitivity.
  • Wavelength accuracy ±0.3nm (Automatic Wavelength Correction).
  • User-selectable spectral bandwidth between 0.1-5nm.
  • User-friendly design allows easy light source replacement and routine maintenance.
  • Sample compartment design enables the use of a wide range of optional accessories.
  • UV-WIN software offers many operational and data processing capabilities and is supplied as standard with the T8DCS

Specifications

Optical System Double beam 
Scan Speed Selectable
Wavelength Range 190~900nm
Wavelength Accuracy ± 0.3nm
Wavelength Reproducibility ≤ 0.1nm
Spectral Bandwidth Continuous slit 0.1~5.0nm with 0.1nm interval
Photometric Mode Transmittance, Absorbance, Energy Concentration, All Using UVWin Software
Photometric Range -4.0~4.0Abs
Photometric Accuracy ±0.002A (0~0.5A), ±0.004A (0.5~1.0A), ±0.3%T (0~100%T)
Photometric Reproducibility ±0.001A (0~0.5A)
Photometric Noise ±0.0004A (500nm) 30min warm-up
Baseline Flatness ±0.001A (200~850nm)
Baseline Stability ±0.0008A/h (500nm, 0Abs), 2hr warm-up
Stray light ≤ 0.01%T (220nm Nal, 340nm NaNO2)
Standard Functionality No stand alone function
Cell Holder Fixed position sample and reference
Detector Photo multiplier tube
Light Source Tungsten Halogen and Deuterium arc lamps
Display No display, connect with computer
Printer using computer printer
PC Interface USB
Software UV-Win software included
Power Supply Switchable 120~230VAC 50~60Hz
Weight 95 lbs / 43kg
Dimensions (Width, Depth, Height) 545mm, 580mm, 270mm